V2000-c Rfid Access Control User Manual 'link' Today

To modify settings, you must enter Programming Mode. While in this mode, the indicator light changes color (typically flashing orange or red).

In programming mode, press 0 + New 4-8 Digit Code + # + Repeat New Code + # . User Management

Enter Programming Mode -> Press 2 + [Read Card] + # .

Ensure you are using a 125 kHz EM-frequency card. Mifare 13.56 MHz cards are incompatible with the V2000-C standard reader. V2000-c Rfid Access Control User Manual

Press * + Master Code + # (The indicator light changes color or flashes slowly).

| Problem | Likely Cause | Solution | | :--- | :--- | :--- | | No LED / No beep | Power failure | Check 12V supply polarity. | | Card not working | Wrong frequency / Not added | Ensure card is 125KHz or 13.56MHz. | | Door won’t lock | Wiring to NC/COM reversed | Swap Green (NC) and White (COM) wires. | | Alarm always beeps | Door sensor open | Disable sensor (Command 22 0 #). |

The V2000-C RFID access control system is a robust and secure solution for managing access to various areas or resources. By following this user manual, administrators and users can understand the features, installation, configuration, and operation of the system. Regular maintenance and upgrades will ensure the system continues to provide efficient and secure access control. If you have any questions or concerns, please refer to the troubleshooting guide or contact the manufacturer's technical support team. To modify settings, you must enter Programming Mode

Proper installation is crucial for the stability of the system.

: This document is compiled from multiple original V2000-C manuals and product specifications. The exact jumper labels (J6 vs S16) and minor programming steps may vary slightly depending on the OEM version or board revision. Always refer to the specific manual provided with your device.

| Action | Method | | :--- | :--- | | Open Door with Card | Swipe registered card near reader. | | Open Door with PIN | Enter [User PIN] + # . | | Open Door with Card + PIN | Swipe card, then enter PIN within 5 seconds. | | Exit Button | Press button (wired to BLUE/BROWN). | User Management Enter Programming Mode -> Press 2

: Relay Normally Closed (NC) – Connects to Fail-Safe locks (Magnetic Locks) YELLOW : Open Button (PUSH) – Connects to the exit button

The manual dedicates its first sections to the physical setup, which is often the most daunting part for non-technical users.

A:

The V2000-c is a standalone access control keypad that utilizes RFID card technology and a numeric keypad for secure entry. To ensure proper setup, please verify the following technical specifications:

The back of the V2000-C features a wiring block. Correct wiring prevents short circuits and equipment damage. Wire Color / Label Description Power Positive Connects to 12V DC positive power supply GND Power Negative Connects to power supply ground PUSH Low-level Trigger Connects to exit button or power supply push terminal OPEN Door Button Connects to one side of the exit button NC Normally Closed Connects to the positive side of a Magnetic Lock NO Normally Open Connects to the positive side of an Electric Strike COM Common Terminal